Sign In | Join Free | My xuijs.com
China Yong Xing Boiler Group Co.,Ltd logo
Yong Xing Boiler Group Co.,Ltd
Yong Xing Boiler Group Co.,Ltd Service customer with profession
Active Member

7 Years

Home > Oil Fired Steam Boiler >

Diesel Fire Tube Cylindrical Boiler Oil Fired Central Heating Boilers Low Dust

Yong Xing Boiler Group Co.,Ltd
Contact Now

Diesel Fire Tube Cylindrical Boiler Oil Fired Central Heating Boilers Low Dust

Brand Name : YONGXING

Model Number : WNS4-1.25/1.6/2.5-YQ

Certification : ISO9001,ISO14001,A-CLASS,SGS,BV

Place of Origin : HENAN PROVINCE

MOQ : 1set

Price : negotiable

Payment Terms : T/T,L/C,Western Union

Supply Ability : 1000SETS/MONTH

Delivery Time : 15-30DAYS

Packaging Details : Nude packing+wooden box+steel box ,and etc.

FUEL : Light oil, Diesel Oil, Kerosene Oil, Heavy oil

PRESSURE : 10bar,12.5bar,16bar,25bar

Boiler capacity : 3Ton / hr

Boiler water capacity : 6-8m3

Oil consumption : 254kg/hr

Boiler efficiency : 94%

Name : Diesel Oil Hot Water Furnace

Material : Q345R,Q245R Steel Plate

Output : Hot Water

Structure : Fire Tube

Color : optional

Pressure : Low Pressure

Contact Now

Factory directly sale WNS3-1.25-YQ with 8 year quality ensurance and supply boiler repair

Yongxing oil fired steam boiler currently Advantages :


1. Low dust, SO2, NOx emission, dust emission concentration < 30mg/m3, SO2 & NOx emission concentration < 30mg/m3.
2. Our gas fired steam boiler with strict quality control system. From the material, welding, to finished boiler shipment, from project , establishment, drawing design, to final audit.
3. Each boiler system part comes from first class brand all over the world and China, ensure our product quality.
4. We will give you the best after sales services and send our engineer to your factory to give you the complete installation and comssion guidance.

3 ton steam boiler feed water request normally :

Boiler feed water should meet GB/T1576-2008 "Industrial Boiler Water Quality"

3 ton steam boiler Boiler technical data for reference :
Rated Rated working Rated steam Suitable Feed water
Model output pressure temperature fuel kind temperature
(t/h) (Mpa) (ºC) (ºC)
WNS0.5-0.7/1.0/1.25-YQ 0.5 0.7/1.0/1.25 170/184/194 heavy oil/light oil,natural gas/lpg/city gas 20
WNS0.7-0.7/1.0/1.25-YQ 0.7 0.7/1.0/1.25 170/184/194 20
WNS0.8-0.7/1.0/1.25-YQ 0.8 0.7/1.0/1.25 170/184/194 20
WNS1-0.7/1.0/1.25-YQ 1 0.7/1.0/1.25 170/184/194 20
WNS1.5-0.7/1.0/1.25-YQ 1.5 0.7/1.0/1.25 170/184/194 20
WNS2-1.0/1.25/1.6-YQ 2 1.0/1.25/1.6 184/194/204 20
WNS3-1.0/1.25/1.6-YQ 3 1.0/1.25/1.6 184/194/204 20
WNS4-1.0/1.25/1.6-YQ 4 1.0/1.25/1.6 184/194/204 20
WNS5-1.0/1.25/1.6-YQ 5 1.0/1.25/1.6 184/194/204 20
WNS6-1.0/1.25/1.6-YQ 6 1.0/1.25/1.6 184/194/204 20
WNS8-1.25/1.6-YQ 8 1.25/1.6 194/204 20
WNS10-1.25/1.6-YQ 10 1.25/1.6 194/204 20
WNS12-1.25/1.6-YQ 12 1.25/1.6 194/204 20
WNS15-1.25/1.6-YQ 15 1.25/1.6 194/204 20
WNS20-1.25/1.6-YQ 20 1.25/1.6 194/204 20

Where our products are sold, we will provide corresponding installation and after-sale services. Solve the troubles of installing and selling after-sales for customers.

Fuel gas boiler maintenance
For maintenance of boiler rooms for more than two years, professional maintenance measures should be taken.

1, Safety reasons: The boiler belongs to special equipment and is a highly mechatronic product. If the inspection and maintenance are not timely, the line will be aging; the oil circuit, oil pump and oil nozzle will be blocked and worn; the gas engine valve group will not seal well, leak and stay. Under security risks.


2, energy-saving reasons: regular use of instruments for gas testing, so that combustion is sufficient and reasonable, to achieve energy-saving effects.


3, environmental reasons: the use of instrument testing, to promote emissions standards, free of pollution


Fuel gas burner maintenance
Burner operating procedures


First, the inspection of the fuel machine before commissioning has three aspects:
1. Check if the diesel is in place, the fuel line is clean and unobstructed, and the valve is open.
2. Whether there is pipeline leakage or not, the pipeline installation is reasonable.
3. Whether the oil returning oil pipeline is installed correctly, the return oil pipe is not allowed to install the valve


Second, the internal inspection of the fuel machine
1. Whether the burner of the burner is installed and the ignition electrode is adjusted.
2. Is the motor rotating in the correct direction?
3. Whether the external circuit connection meets the requirements.
4. The cold state simulation of the burner is carried out according to the line condition, and it is observed whether the various components of the equipment in operation are normal and whether the flame detection protection part is normal.


Third, the debugging of the burner
1. Check if the external diesel is in place, the pipeline is unobstructed, and the external power supply is in place.
2. Adjust the load of the burner to a small load, adjust the ignition position to a small load, turn off the large load to ignite and observe the flame condition, and adjust the servo motor or damper according to the flame condition.
3. When adjusting the fire output of the burner, it is necessary to adjust from a relatively small load to a large load according to the load condition of the heat equipment, and adjust the servo motor or the damper according to the situation.
4. Observe the flames for partial fire, insufficient flame combustion, vibration and other phenomena.
5. After the adjustment, multiple ignitions should be performed to see if the ignition is good.

Diesel Fire Tube Cylindrical Boiler Oil Fired Central Heating Boilers Low Dust
Fourth, the site requirements:
1. Unrelated personnel who are involved in commissioning work are required to leave the job site.
2. It is forbidden to work in any other way (such as electric welding, gas cutting, etc.).
3. In order to ensure the personal safety of the commissioning personnel, when the burner is ignited, it should be 1 meter away from the side of the burner. When the flame is stable, the flame can be observed at the sight glass and the next step of power adjustment and other adjustments.


Fifth Precautions for commissioning and maintenance of fuel oil
1. When the secondary combustion program of the fuel burner fails continuously, it should be stopped to check whether the fuel supply system of the burner is normal, whether the circuit connection is correct, and the burner can be restarted after the fault is cancelled.
2. It is strictly forbidden to smoke, weld, cut and other illegal operations on site.
3. In the debugging work, it must be done seriously, safely and efficiently.
4. It is forbidden to use non-explosion-proof electric power tools on site.
5. Explain the safety operation precautions to the customer in detail.
6. It is required to check if the oil circuit is open before starting the machine.
7. It is recommended not to commission the fuel machine at night.
8. At the end of commissioning, the operator should be trained to use the direction of operation and establish the flow of operations if necessary.


Feature:

1. Design with three pass structure horizontal, support OEM ,absorbs the thermal expansion effectively. Corrugated furnace large diameter, large combustion space, high combustion efficiency.
2. Equipped with multiple safety protection devices, such as pressure controller, pressure transmitter, water level alarm, safety valve, etc.
3. Adopts PLC full automatic intelligent control cabinet and interlock protection program, has the protection function of water shortage, over pressure, over temperature, gas leakage, flame out, electric leakage, and phrase-lacking or overloading of motor, etc.
4. Equipped with reliable boiler auxiliaries,such as world known famous burner(Riello, Baltur, Unigas,Weishaupt,etc), international famous brand water pump(Grundfos, CNP), Siemens brand electric control elements, Fleck brand water softemner from USA, etc
5. Adopt the latest boiler technology, 100% flaw detection test, high quality, and long working life, low maintenance fee.

Diesel Fire Tube Cylindrical Boiler Oil Fired Central Heating Boilers Low Dust

Flue gas emissions comply with the environmental requirements of the first-class regions of the country.

Water supply hardness: 0.03mmol / L,
Oxygen content: 0.1mg / L,
Boiler water full alkalinity: 6 ~ 24mmol / L,
PH (25 ° C): 10 ~ 12.

The soften water will promise boiler long life time .


Product Tags:

oil central heating boilers

      

oil powered boiler

      
Best Diesel Fire Tube Cylindrical Boiler Oil Fired Central Heating Boilers Low Dust wholesale

Diesel Fire Tube Cylindrical Boiler Oil Fired Central Heating Boilers Low Dust Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Yong Xing Boiler Group Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0